LAB SAFETY CHECKLIST
|
✔ |
Chemical Type |
Description |
✔ |
Equipment Type |
Description |
| |
General |
Solvent resistant covered Floors |
|
Autoclave |
Adequate space for use, maintenance and material storage |
| |
|
Ventilated Storage |
|
|
Drainage to minimixe flooding |
| |
|
Solid, Sturdy Shelves |
|
Fume Hood |
Bypass style, No Aux. air hoods |
| |
|
separated Chemical Waste Storage |
|
|
Located to minimize cross drafts and turbulance |
| |
|
Clearly labeled eyewash and safety shower within 10 seconds traveling distance |
|
|
Face velocity 100 - 125 linear feet per minute |
| |
|
Fire Extinguisher mounted near entrance of work or storage area |
|
|
Continuous Monitoring Device |
| |
Flammable Liquids |
More than 10 gallons in a lab needs flammable liquid storage cabinets |
|
|
No Fire Dampers in exhaust ducts |
| |
|
Storage not allowed below grade |
|
|
Debris Screen |
| |
Corrosives |
Storage in low cabinets or shelves |
|
|
Single vertical sash |
| |
Perchloric Acid |
Stainless Steel hood with washdown system |
|
Distillation Hood |
Hood Fire Suppression System |
| |
Radioactive Materials |
Physically separated eating and drinking areas |
|
Environmental Chamber |
Emergency Lighting |
| |
|
separate radioactive materials from other areas |
|
|
Visual or audible local alarm if regular alarm system cannot be heard inside the chamber |
| |
|
separate space for radioactive waste storage |
|
Cryogenic Liquid Tanks |
Controls secure or located to prevent accidental opening |
| |
Biological Agents |
Handwashing sinks with elbow or electronic controls |
|
|
Not below grade or near glass doors and windows |
| |
|
separate space for Medical Waste Storage |
|
Lasers |
Ground Fault circuit interrupters near water cooling systems |
| |
Highly Toxic Chemicals |
Handwashing sinks with elbow or electronic controls |
|
|
Carbon dioxide fire extinguishers, rather than dry chemical extinguishers |
| |
Highly Toxic Gases |
Vented Gas Cabinet |
|
Equipment needing Cooling |
Chilled Water Loops |
| |
|
Coaxial Tubing |
|
Vacuum Lines |
Local pumps preferred over central system |
| |
|
Alarmed Vapor Sensors |
|
|
Cold Traps or filters to prevent contamination |